首页> 外文OA文献 >Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes
【2h】

Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes

机译:在非真空或真空过程的消毒过程中,使用测温方法研究具有窄内腔的牙科手机中的蒸汽渗透

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background:\ud\udDental handpieces are required to be sterilized between patient use. Vacuum steam sterilization processes with fractionated pre/post-vacuum phases or unique cycles for specified medical devices, are required for hollow instruments with internal lumens to assure successful air removal. Entrapped air will compromise achievement of required sterilization conditions. Many countries and professional organisations still advocate non-vacuum sterilization processes for these devices.\ud\udAim:\ud\udTo investigate non-vacuum downward/gravity displacement, type-N steam sterilization of dental handpieces, using thermometric methods to measure time to achieve sterilization temperature at different handpiece locations.\ud\udMethods:\ud\udMeasurements at different positions within air turbines were undertaken with thermocouples and dataloggers. Two examples of commonly used UK benchtop steam sterilizers were tested; a non-vacuum benchtop sterilizer (Little Sister 3, Eschmann, UK) and a vacuum benchtop sterilizer (Lisa, W&H, Austria). Each sterilizer cycle was completed with three handpieces and each cycle in triplicate.\ud\udFindings:\ud\udA total of 140 measurements inside dental handpiece lumens were recorded. We demonstrate that the non-vacuum process fails (time range 0-150 seconds) to reliably achieve sterilization temperatures within the time limit specified by the International standard (15 seconds equilibration time). The measurement point at the base of the handpiece failed in all test runs (n=9) to meet the standard. No failures were detected with the vacuum steam sterilization type B process with fractionated pre-vacuum and post-vacuum phases.\ud\udConclusion:\ud\udNon-vacuum downward/gravity displacement, type-N steam sterilization processes are unreliable in achieving sterilization conditions inside dental handpieces and the base of the handpiece is the site most likely to fail.
机译:背景:\ ud \ ud牙科手机需要在患者使用之间进行消毒。对于带有内部腔的中空器械,需要采用真空蒸汽灭菌工艺,该工艺具有分阶段的真空前/真空后阶段或特定医疗设备的独特循环,以确保成功去除空气。夹带的空气将损害实现所需灭菌条件的能力。许多国家和专业组织仍然提倡对这些设备进行非真空灭菌工艺。\ ud \ ud目标:\ ud \ ud为研究牙科手机的非真空向下/重力位移,N型蒸汽灭菌,使用测温方法测量时间, \ ud \ ud方法:\ ud \ ud使用热电偶和数据记录仪在涡轮机的不同位置进行测量。测试了两个英国常用台式蒸汽灭菌器的例子;非真空台式灭菌器(Little Sister 3,英国Eschmann,英国)和真空台式灭菌器(Lisa,W&H,奥地利)。每个灭菌器循环用三个手机完成,每个循环一式三份。\ ud \ ud结果:\ ud \ ud总共记录了牙科手机内腔内的140个测量值。我们证明了非真空过程无法(在0-150秒的时间范围内)在国际标准规定的时限(平衡时间为15秒)内无法可靠地达到灭菌温度。在所有测试运行中,机头底部的测量点均未达到标准要求(n = 9)。 B级真空蒸汽灭菌工艺在真空前和真空后均分馏,未发现任何故障。\ ud \ ud结论:\ ud \ ud非真空向下/重力位移,N型蒸汽灭菌工艺对实现灭菌不可靠牙科手机内部和手机底座的状况是最可能发生故障的部位。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号