A new technique for detecting partial discharges within an on-line power transformer subjected to interference

机译:检测在线电力变压器内局部放电受干扰的新技术

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Increased demand on power transformers, due to the extension of equipment lifetimes and a trend to lower costs, has led to a need for condition based maintenance. However, there are currently no established techniques to accurately monitor and diagnose faults in real-time while the transformer is on-line. A major factor inthe degradation of transformer insulation is partial discharging which, if left unattended, will eventually cause complete insulation failure. A partial discharge detection system (PDDS) is presented for electrically identifying partial discharge pulses and determining the number of partial discharge sources while the transformer ison-line and subjected to external interference. Current and voltage transducers are placed on the transformer bushings rendering it unnecessary for the transformer to be disconnected or opened. Partial discharge pulses are identified within narrowband and pulse interference using digital signal processing techniques which include an automated Fourier domain threshold filter and a continuous wavelet directional coupling filter. If multiple sources are active, the partial discharge pulses are grouped by a clustering neural network. Two 7.5kVA, 11kV transformers wereused to conduct testing of the PDDS. High recognition rates of artificial partial discharge pulses were achieved in an off-line transformer, while a previously unknownnatural partial discharge source was identified in the second energised transformer.
机译:由于设备寿命的延长以及成本降低的趋势,对电力变压器的需求增加,导致需要进行基于状态的维护。但是,目前尚无成熟的技术可以在变压器在线时实时准确地监视和诊断故障。变压器绝缘性能下降的一个主要因素是局部放电,如果不加注意,则会最终导致完全绝缘故障。提出了一种局部放电检测系统(PDDS),用于在变压器在线且受到外部干扰时电气识别局部放电脉冲并确定局部放电源的数量。电流和电压传感器放置在变压器套管上,因此无需断开或打开变压器。使用包括自动傅里叶域阈值滤波器和连续小波定向耦合滤波器在内的数字信号处理技术,可以在窄带和脉冲干扰内识别局部放电脉冲。如果有多个源处于活动状态,则局部放电脉冲将通过聚类神经网络进行分组。使用两个7.5kVA,11kV变压器对PDDS进行测试。在离线变压器中获得了较高的人工局部放电脉冲识别率,而在第二个通电变压器中发现了以前未知的自然局部放电源。

著录项

  • 作者

    Hardie S.R.; Bodger P.S.;

  • 作者单位
  • 年度 2006
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号