Harmonic domain modelling of direct connected generator and HVDC convertor units.

机译:直接连接的发电机和HVDC转换器单元的谐波域建模。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This thesis describes a new method of analysing the harmonic content of direct connected generator-HVdc convertor units. Existing analysis techniques are reviewed, and their strengths and weaknesses are discussed. A set of simultaneous equations that fully describes the harmonic interaction among the generators, convertors and the dc system is derived. The simultaneous equations are solved using Newton's method. By exploiting the sparse nature of the Jacobian matrix of partial derivatives, the solution is obtained quickly. The solution of a test system is verified by means of dynamic simulations. The developed unified solution is a significant improvement on existing harmonic analysis. A harmonic model of the salient-pole generator is developed and validated against time domain simulations and harmonic measurement results obtained from the Benmore convertor station when being operated as a group connected unit. The relationship between the generator terminal voltages and currents in the presence of saliency can be represented by analytical expressions in sequence components, derived from normal machine parameters. The effect of generator saturation on the harmonic content is not significant. The effect of rotor angle on the commutation process in the presence of saliency is significant in direct connected units. By choosing the generator terminal voltage as the firing angle reference, existing firing control for conventional HVdc schemes can be used for direct connected units with practically no modification. Provided that the nominal firing angles are kept within the restriction limits, imposed by the overlap angle, generator terminal power factor, equivalent continuous negative-sequence harmonic loading and the number of generators, practically no extra capacity for harmonic current loading is required in direct connected units. The generator harmonic ratings can be taken at the nominal speed and rated power output. Conventional tuned dc filters are ineffective in adjustable speed operation. Finally, detailed three-phase harmonic information of the Benmore convertor station when being operated in the group connected mode is collected and discussed. The test results are used for validating the developed models, and they also provide valuable evidence of the feasibility of direct connected units.
机译:本文介绍了一种分析直联发电机-HVdc转换器单元谐波含量的新方法。审查了现有的分析技术,并讨论了它们的优缺点。导出了一组联立方程,这些方程完全描述了发电机,转换器和直流系统之间的谐波相互作用。用牛顿法求解联立方程。通过利用偏导数雅可比矩阵的稀疏性质,可以快速获得解。测试系统的解决方案通过动态仿真进行验证。开发的统一解决方案是对现有谐波分析的重大改进。开发凸极发电机的谐波模型,并针对时域仿真和作为一组连接单元运行时从本莫尔换流站获得的谐波测量结果进行验证。在存在显着性的情况下,发电机端子电压和电流之间的关系可以通过序列分量的解析表达式来表示,这些表达式由正常的机器参数得出。发电机饱和度对谐波含量的影响不明显。在存在显着性的情况下,转子角对换向过程的影响在直接连接单元中很明显。通过选择发电机端电压作为点火角参考,常规HVdc方案的现有点火控制可直接用于直接连接的单元,几乎无需任何修改。如果名义点火角保持在由重叠角,发电机终端功率因数,等效连续负序谐波负载和发电机数量所施加的限制范围内,则在直接连接中实际上不需要额外的谐波电流负载能力单位。发电机谐波额定值可以在额定转速和额定功率输出下获得。常规的调谐直流滤波器在调速操作中无效。最后,收集并讨论了本摩尔换流站以群联模式运行时的详细三相谐波信息。测试结果用于验证开发的模型,它们还提供了直接连接单元可行性的宝贵证据。

著录项

  • 作者

    Dinh Nhut-Quang;

  • 作者单位
  • 年度 1998
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号