首页> 外文OA文献 >Single camera 3D planar Doppler velocity measurements, using two frequency planar Doppler velocimetry (2v-PDV) and imaging fibre bundles
【2h】

Single camera 3D planar Doppler velocity measurements, using two frequency planar Doppler velocimetry (2v-PDV) and imaging fibre bundles

机译:使用两个频率平面多普勒测速仪(2v-PDV)和成像光纤束的单相机3D平面多普勒速度测量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A modified Planar Doppler Velocimetry (PDV) technique, two frequency PDV (2v-PDV), is described that allows measurements of the velocity field over a plane defined by a laser light sheet using sequential illumination of the flow with two closely separated (&IGHz) frequencies of laser light. This allows a common-path imaging head to be used containing a single CCD camera instead of the usual camera pair. The problem of image misalignment is now avoided and the polarisation sensitivity of the beam splitter used in two camera imaging heads is also removed. Cost efficiency is improved by the simplification of the system. This paper describes the development of a 2v-PDV system using a continuous wave argon ion laser capable of making time-averaged velocity measurements. Initially a single velocity component system was constructed using acousto-optic modulators to produce the two illumination frequencies required. The system was then expanded to make 3D velocity measurements using a single CCD camera and multiple coherent imaging fibre bundles. Measurements were made on the rotating disc, in order to assess error level in the measurements, and on a seeded axisymmetric air jet. A method of improving the sensitivity of the 2v-PDV system is demonstrated by using both the rising and falling slopes of the iodine absorption line. Reductions in the error levels of velocity measurements of approximately 40% can be achieved using this increased sensitivity method.
机译:描述了一种改进的平面多普勒测速(PDV)技术,即两个频率的PDV(2v-PDV),该技术允许通过使用两个紧密分开的(&IGHz)顺序照射流,在由激光片定义的平面上测量速度场激光的频率。这允许使用包含单个CCD摄像机而不是通常的摄像机对的共路径成像头。现在避免了图像未对准的问题,并且还消除了在两个相机成像头中使用的分束器的偏振灵敏度。通过简化系统可以提高成本效率。本文描述了使用连续波氩离子激光器能够进行时均速度测量的2v-PDV系统的开发。最初,使用声光调制器构建了一个单速分量系统,以产生所需的两个照明频率。然后,使用单个CCD摄像机和多个相干成像光纤束将系统扩展为进行3D速度测量。为了评估测量中的误差水平,在转盘上以及在带种子的轴对称空气喷嘴上进行了测量。通过使用碘吸收线的上升和下降斜率,证明了一种提高2v-PDV系统灵敏度的方法。使用这种提高灵敏度的方法,可以将速度测量的误差水平降低约40%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号