首页> 外文OA文献 >Investigation of a fibre-optic Fizeau interferometer configuration and coherent fibre-optic imaging bundles for optical coherence tomography
【2h】

Investigation of a fibre-optic Fizeau interferometer configuration and coherent fibre-optic imaging bundles for optical coherence tomography

机译:用于光学相干断层扫描的光纤Fizeau干涉仪配置和相干光纤成像束的研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Currently several medical imaging techniques are in operation in clinicalenvironments that help the doctors to diagnose diseases before proceeding totreatment. This research investigated and implemented configurations for a medicalimaging technique called Optical Coherence Tomography (OCT).The Michelson interferometer has been the principal configuration for OCT systems.For endoscopic OCT applications though such a configuration is susceptible topolarisation induced signal fading due to environmental changes within the samplearm, like fibre bending and temperature fluctuations. The development and testing ofa Fizeau interferometer based OCT system demonstrate the elimination of thispolarisation induced signal fading as the sample and reference arm of theinterferometer experience the same environmental changes. The Fizeau interferometeris formed between the end of the fibre and the sample itself. A secondary processinginterferometer is used in this configuration, to compensate the path difference inherentto the Fizeau configuration. Longitudinal resolution is about 19 m in air, and lateralresolution about 23 m. A signal-to-noise ratio of about 80 dB was achieved with thissystem and several sets of image data were collected from laboratory and biologicalsamples.An OCT system based on a Fizeau interferometer incorporating a coherent fibreimaging bundle was also investigated. Fibres in the bundle are accessed sequentiallyby a beam focused onto the input face of the bundle, allowing 2D information to beacquired using point detection. Incorporating a fibre optic imaging bundle in Fizeaubased interferometer OCT allows mechanical scanning parts to be removed from thesample arm, resulting in a passive probe. Such a configuration can form a compact,robust and “downlead insensitive” OCT system and is a strong candidate for in vivoapplications. The performance of leached and wound coherent fibre optic bundles wasaccessed and an analysis is presented. The longitudinal resolution of the systemdeveloped was about 10 m in air, and lateral resolution about 9 m. This thesisdemonstrates several sets of image data that were collected from various samplesusing a Fizeau interferometer based OCT incorporating coherent imaging bundles. 2Dimage data captured by such a configuration are presented and reported for the firsttime in this thesis.
机译:当前,几种医学成像技术正在临床环境中运行,这些技术可帮助医生在进行治疗之前诊断疾病。这项研究调查并实现了称为光学相干断层扫描(OCT)的医学成像技术的配置。迈克尔逊干涉仪一直是OCT系统的主要配置。对于内窥镜OCT应用,尽管这种配置易受偏振光引起的信号衰减的影响,但由于环境中的环境变化样品臂,例如纤维弯曲和温度波动。基于菲索(Fizeau)干涉仪的OCT系统的开发和测试证明,消除了这种偏振引起的信号衰减,因为干涉仪的样品和参考臂经历了相同的环境变化。 Fizeau干涉仪形成在光纤末端和样品本身之间。在此配置中使用了辅助处理干涉仪,以补偿Fizeau配置固有的路径差。空中的纵向分辨率约为19 m,横向分辨率约为23 m。该系统实现了约80 dB的信噪比,并从实验室和生物样本中收集了几套图像数据。还研究了基于Fizeau干涉仪并结合了相干光纤成像束的OCT系统。束中的光纤通过聚焦在束输入面上的光束顺序访问,从而可以使用点检测来获取2D信息。在基于Fizeau的干涉仪OCT中集成光纤成像束,可以从样品臂上卸下机械扫描部件,从而形成无源探头。这样的配置可以形成紧凑,稳健和“对低端引线不敏感”的OCT系统,并且非常适合用于体内应用。获得了浸出和缠绕的相干光纤束的性能,并进行了分析。所开发系统的纵向分辨率在空中约为10 m,横向分辨率约为9 m。本文展示了使用基于Fizeau干涉仪的OCT并结合了相干成像束从各种样品中收集的几组图像数据。本文首次提出并报道了通过这种配置捕获的二维图像数据。

著录项

  • 作者

    Sarantavgas Georgios;

  • 作者单位
  • 年度 2008
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号