首页> 外文OA文献 >Discrimination of Real and Sham Acupuncture Needles Usingudthe Park Sham Device: A Preliminary Study
【2h】

Discrimination of Real and Sham Acupuncture Needles Usingudthe Park Sham Device: A Preliminary Study

机译:使用 ud区分实针和假针Park Sham设备:初步研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective: To evaluate the blinding effectiveness of theudPark sham acupuncture device using participants’ ability touddiscriminate between the real and sham acupuncture needles.udDesign: The design was a yes-no experiment. Judgmentsudwere made on whether the real or sham acupuncture needle wasudadministered.udSetting: University laboratory.udParticipants: Healthy, acupuncture-naive university studentsudand staff (N20; median age, 22y; range, 18 – 48y) recruited through convenience sampling.udInterventions: Participants made yes-no judgments onudwhether the real or sham needle was administered to 8 acupoints (4 traditional and 4 nontraditional) along the Pericardium meridian(Pericardium 3 to Pericardium 6) on the dominant forearm.udMain Outcome Measures: The accuracy index, d=, of participants’ ability to discriminate between the real and sham needles(discriminability) was computed for the traditional alone, the nontraditional alone, and a combination of both types of acupoints.udResults: The participants’ d= between the real and shamudneedles was not statistically significant from d' = equal to 0 for the combined traditional and nontraditional acupoints comparison and the nontraditional acupoints alone comparison (combined, t(19)=1.20, P=.25; nontraditional, t(19)=.16, P=.87).udHowever, the participants’ d' = was statistically significant from d' = equal to 0 for the traditional acupoints comparison (t(19)=2.096, P=.049).udConclusions: The Park sham acupuncture device appears toudbe effective in blinding participants to real acupuncture intervention when it is applied to the nontraditional acupoints and when traditional and nontraditional acupoints are combined on the forearm along the pericardium meridian. However, the sham device does not appear to blind participants effectively when traditional acupoints alone are used for the same context.udKey Words: Acupuncture; Placebos; Rehabilitation; Signaluddetection, psychological; Validation studies at topic.
机译:目的:利用参与者区分真实针头和假针头的能力来评估udPark假针刺设备的致盲效果。udDesign:设计是一个“是/不是”实验。对是否使用真正的或假针灸针进行了判断。 ud设置:大学实验室。 ud参与者:健康,针灸纯真的大学生 udand员工(N20;中位年龄22岁;范围18岁至48岁) ud干预措施:参与者是否对沿优势前臂的心包子午线(心包3到心包6)的8个穴位(4个传统针灸和4个非传统针灸)施用了真针或假针? ud主要结果指标:针对传统针灸,非传统针灸以及两种类型的穴位的组合,计算出参与者区分实针和假针的能力(可辨别性)的准确度指标d =。对于传统和非传统穴位比较以及非传统针刺比较,从d'= 0开始,参与者的真实和假针之间的d =在统计学上不显着ts单独比较(组合,t(19)= 1.20,P = .25;非传统,t(19)=。16,P = .87)。 ud但是,对于传统穴位比较,参与者的d'=从d'= 0开始具有统计学意义(t(19)= 2.096,P = .049)。 ud结论:帕克假手术针刺装置适用于非传统穴位,并且在沿心包子午线的前臂上结合了传统和非传统穴位时,似乎可以有效地使参与者盲目接受真正的针灸干预。但是,仅在同一环境中使用传统穴位时,假手术装置似乎并不能有效地使参与者盲目。安慰剂;复原;信号侦测,心理;主题验证研究。

著录项

  • 作者

    Tan Chee-Wee;

  • 作者单位
  • 年度 2009
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号