In radiation therapy of cancer, modeling the dose to the patient is very important. Several computational algorithms are available, where some model dose in heterogeneous tissue better than others. After implementation of stereotactic radiotherapy of lung cancer at the University Hospital of North Norway, where high dose are given with high precision, it is desirable to look at the difference in the calculated dose for the established algorithm AAA, and newcomer Acuros, in heterogeneous tissue. Dose measurements were made using radiochromic film and ionization chambers in a lung phantom, and compared with calculated dose distributions for different energies which can be used in the treatment of lung tumors. In addition, patients previously treated stereotactically to the lung was replanned using Acuros and volume doses were compared. Results from the lung phantom show that Acuros calculates lower dose in light lung tissue compared to AAA but it is difficult to make measurements the dose in low density media for absolute comparisons. Patient plans calculated by Acuros show correspondingly a much lower dose to lung tissue surrounding a tumor and an overall lower dose given to heterogeneous tissue relative to AAA calculations. To acquire better estimations of actual doses given during radiotherapy of lung tumors, the implementation of Acuros should be considered.
机译:在癌症的放射治疗中,对患者的剂量建模非常重要。有几种计算算法可用,其中某些模型在异质组织中的剂量要优于其他模型。在北挪威大学医院实施了肺癌的立体定向放射治疗后,该实验室以高剂量高精度给药,因此,有必要查看异类组织中已建立的算法AAA和新来的Acuros在计算剂量上的差异。在肺部幻像中使用放射变色膜和电离室进行剂量测量,并将其与可用于治疗肺肿瘤的不同能量的剂量分布进行比较。此外,使用Acuros重新规划了先前接受立体定向肺部治疗的患者,并比较了剂量。肺部幻影的结果表明,与AAA相比,Acuros计算出的轻度肺部组织剂量更低,但是很难在低密度介质中进行剂量测量以进行绝对比较。由Acuros计算出的患者计划显示,相对于AAA计算,对应于肿瘤周围肺组织的剂量要低得多,而给予异质组织的总体剂量要低得多。为了获得对肺肿瘤放疗期间实际剂量的更好估计,应该考虑采用Acuros。

著录项

  • 作者

    Perander Kristine;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号