Today, manufacturers of medium voltage equipment are searching for alternatives to sulfur hexafluoride (SF$_6$) as the insulating gas. The advantageous thermal and molecular properties make it suitable as an insulating gas, however, it is a strong green house gas. With the present climate challenges, one of the measures of reducing emission of climate gases is to phase out the use of SF$_6$-insulated medium voltage switchgears. An environmentally friendly alternative is air, which has a lower withstand voltage than SF$_6$. For backwards compatibility, the primary manufacturers in this development is optimization (to compensate for lower withstand) of current designs without increasing the dimensions. This work have investigated the breakdown voltage and optical detected partial discharges activity during AC stress in ambient air. The measurements have been carried out for two cylindrically symmetric test objects, containing triple junctions. These measurements have been supplemented by electric field simulations carried out in COMSOL Multiphysics. Various gap distances between the electrodes have been tested. Correlation between gap distance, breakdown voltage, partial discharge activity, and inception voltage have been determined.The withstand voltage of the investigated test objects proved to have a higher value than the dimensioning withstand voltage for streamer propagation in a sphere-plane arrangement. Characteristic pattern of the partial discharge activity, optically detected with a photomultiplier tube, align with the commonly observed phase-resolved pattern for gliding discharges along a surface of a solid dielectric in air. Streamer inception criterion based on applying the background field for calculating resulted in a dimensioning criteria where the withstand voltage of the investigated test objects is lower than the dimensioning inception voltage from calculations of the streamer inception criteria.
机译:如今,中压设备制造商正在寻找六氟化硫(SF $ _6 $)作为绝缘气体的替代品。有利的热和分子性质使其适合用作绝缘气体,但它是强温室气体。面对当前的气候挑战,减少气候气体排放的措施之一是逐步淘汰使用SF $ _6 $绝缘的中压开关设备。环保的替代品是空气,其耐压低于SF $ _6 $。为了向后兼容,此开发中的主要制造商在不增加尺寸的情况下优化了当前设计(以补偿较低的承受力)。这项工作研究了环境空气中的交流应力期间的击穿电压和光学检测的局部放电活动。已经对包含三重结的两个圆柱对称测试对象进行了测量。这些测量已通过COMSOL Multiphysics中进行的电场模拟得到了补充。电极之间的各种间隙距离已经过测试。确定了间隙距离,击穿电压,部分放电活动和起始电压之间的相关性。被研究的测试对象的耐压被证明具有比在球面布置中流光传播的尺寸耐压更高的值。用光电倍增管光学检测的局部放电活性的特征图案与沿空气中固体电介质表面滑动放电的通常观察到的相分辨图案对齐。基于应用背景场进行计算的拖缆起始判据导致了尺寸确定标准,其中所研究的测试对象的耐压低于根据拖缆起始判据的计算得出的尺寸起始电压。

著录项

  • 作者

    Korneliussen Kristine;

  • 作者单位
  • 年度 2016
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号