首页> 外文OA文献 >Development of a novel reagentless, screen– printed amperometric biosensor based on glutamate dehydrogenase and NAD+, integrated with multi–walled carbon nanotubes for the determination of glutamate in food and clinical applications.
【2h】

Development of a novel reagentless, screen– printed amperometric biosensor based on glutamate dehydrogenase and NAD+, integrated with multi–walled carbon nanotubes for the determination of glutamate in food and clinical applications.

机译:基于谷氨酸脱氢酶和NAD +的新型无试剂丝网印刷安培生物传感器的开发,该传感器与多壁碳纳米管集成在一起,用于食品和临床应用中的谷氨酸测定。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A screen printed carbon electrode (SPCE) containing the electrocatalyst Meldola's Blue (MB) has been investigated as the base transducer for a reagentless glutamate biosensor. The biopolymer chitosan (CHIT) and multiwalled carbon nanotubes (MWCNTs) were used to encapsulate the enzyme glutamate dehydrogenase (GLDH) and the co-factor nicotinamide adenine dinucleotide (NAD+). The biosensor was fabricated by sequentially depositing the components on the surface of the transducer (MB-SPCE) in a layer-by-layer process, details of which are included in the paper. Each layer was optimised to construct the reagentless device. The biosensor was used in conjunction with amperometry in stirred solution using an applied potential of +0.1 V (vs. Ag/AgCl). Optimum conditions for the analysis of glutamate were found to be: temperature, 35 °C; phosphate buffer, pH 7 (0.75 mM, containing 0.05 M NaCl). The linear range of the reagentless biosensor was found to be 7.5–105 μM, and limit of detection was found to be 3 μM (based on n = 5, CV: 8.5% based on three times signal to noise) and the sensitivity was 0.39 nA/μM (±0.025, coefficient of variation (CV) of 6.37%, n = 5). The response time of the biosensor was 20–30 s. A food sample was analysed for monosodium glutamate (MSG). The endogenous content of MSG was 90.56 mg/g with a CV of 7.52%. The reagentless biosensor was also used to measure glutamate in serum. The endogenous concentration of glutamate was found to be 1.44 mM (n = 5), CV: 8.54%. The recovery of glutamate in fortified serum was 104% (n = 5), CV of 2.91%.
机译:已经研究了包含电催化剂Meldola's Blue(MB)的丝网印刷碳电极(SPCE)作为无试剂谷氨酸生物传感器的基础传感器。生物聚合物壳聚糖(CHIT)和多壁碳纳米管(MWCNT)用于封装谷氨酸脱氢酶(GLDH)和辅因子烟酰胺腺嘌呤二核苷酸(NAD +)。生物传感器是通过在逐层过程中依次在换能器(MB-SPCE)的表面上依次沉积组件而制成的,其详细信息包含在本文中。优化每一层以构建无试剂装置。在+0.1 V(vs。Ag / AgCl)的施加电势下,将生物传感器与安培计一起在搅拌溶液中使用。发现用于谷氨酸分析的最佳条件为:温度35℃;温度为35℃。磷酸盐缓冲液,pH 7(0.75 mM,包含0.05 M NaCl)。发现无试剂生物传感器的线性范围为7.5–105μM,检测极限为3μM(基于n = 5,CV:基于三倍信噪比的8.5%),灵敏度为0.39 nA /μM(±0.025,变异系数(CV)为6.37%,n = 5)。生物传感器的响应时间为20–30 s。分析食品样品中的味精(MSG)。 MSG的内源含量为90.56 mg / g,CV为7.52%。无试剂生物传感器也用于测量血清中的谷氨酸。发现谷氨酸的内源浓度为1.44 mM(n = 5),CV:8.54%。强化血清中谷氨酸的回收率为104%(n = 5),CV为2.91%。