首页> 美国政府科技报告 >Fatality Assessment and Control Evaluation (FACE) Report for Massachusetts: Employee Electrocuted While Dismantling a Metal Edged Box Resting on a Flexible Electrical Cord, FACE-91-MA-007.
【24h】

Fatality Assessment and Control Evaluation (FACE) Report for Massachusetts: Employee Electrocuted While Dismantling a Metal Edged Box Resting on a Flexible Electrical Cord, FACE-91-MA-007.

机译:马萨诸塞州的死亡率评估和控制评估(FaCE)报告:员工在拆除搁置在柔性电线上的金属边框时电击,FaCE-91-ma-007。

获取原文

摘要

A 24 year old white male wind-up operator was electrocuted when the metal edge of a box he was dismantling severed the insulation on a flexible electrical cord. The box had apparently fallen off the fork lift and was propped on edge by the fork lift which was not operation at the time of the incident. He was breaking off bolts with a hammer and chisel; the weight of the box and the force of the blows exposed the energized electrical wire. The company electrician measured 277 volts and .1 amps subsequent to the fatality. The employee had been breaking apart these metal framed wooden boxes because they were no longer needed by the company. He had been working for 11 hours and forty-five minutes when this fatality occurred. Massachusetts Department of Labor and Industries investigators concluded that, in order to prevent future similar occurrences, employers should: (1) Refrain from using flexible electrical cords as a substitute for fixed wiring. (2) Refrain from using flexible electrical cords where they may be subjected to damage. (3) Ensure that established safety procedures are followed at all times. (4) Discourage the practice of 12 hour work days to avoid employee fatigue. (5) Ensure that the company safety program is comprehensive and includes identification of common electrical hazards.

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号