首页> 美国政府科技报告 >Recommended Operating Procedure No. 51: Glass Source Assessment Sampling System(Glass SASS)
【24h】

Recommended Operating Procedure No. 51: Glass Source Assessment Sampling System(Glass SASS)

机译:推荐的操作程序第51号:玻璃源评估采样系统(玻璃sass)

获取原文

摘要

The report is a recommended operating procedure (ROP), prepared for use inresearch activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The method described is applicable to the stack sampling of flue gas from a rotary kiln and to associated equipment of AEERL's Combustion Research Branch. It has been the standard method of sampling kiln flue gas due to the transient nature of the puff development and its capability to sample the maximum volume over the shortest time period. ROPs describe non-routine or experimental research operations where some judgment in application may be warranted. ROPs may not be applicable to activities conducted by other research groups, and should not be used in place of standard operating procedures. Use of ROPs must be accompanied by an understanding of the purpose and scope. Questions should be directed to the author.