首页> 美国政府科技报告 >Screened-Room Measurements on the NIST Spherical-Dipole Standard Radiator
【24h】

Screened-Room Measurements on the NIST Spherical-Dipole Standard Radiator

机译:NIsT球形偶极标准散热器的屏蔽室测量

获取原文

摘要

We report the results of a study of measurements of radiated emissions from theNIST spherical-dipole standard radiator in several screened rooms. The study serves as a demonstration of possible applications of the standard radiator as well as an investigation of radiated-emissions measurements in screened rooms. The screened-room measurements were performed in accordance with MIL-STD 462 (1967). Large differences occurred in the field intensity measured at different days at the same laboratory. There was a systematic difference at low frequencies between the screened-room results obtain in a transverse electromagnetic (TEM) cell, open-area test site (OATS), and anechoic chamber.