首页> 美国政府科技报告 >Residential Hot Water Usage: A Review of Published Metered Studies. TopicalReport, August-December 1994
【24h】

Residential Hot Water Usage: A Review of Published Metered Studies. TopicalReport, August-December 1994

机译:住宅热水使用:已发表的计量研究综述。 TopicalReport,1994年8月至12月

获取原文

摘要

The report presents a review of residential hot water usage studies. The studiesincluded were published and publicly available, they measured actual hot water usage or energy usage, and they had sufficient demographic information to determine the number of people per household. The available hot water usage data were normalized to a 135 F setpoint temperature to eliminate the variations in usage caused by different water heater thermostat settings. Typical hot water usage as a function of family size was determined from linear regression analyses of the normalized metered studies' data points. A national average hot water usage of 53 gallons per day was determined from the regression analyses and census data on average household size. The review of metered studies also shows that there is no discernible difference in hot water usage for households with either electric or gas water heaters.