The testing of 12-inch turbine meters in the MRF-HPL was intended to obtainindependent data on how well commonly used turbine meters perform when calibrated and used on natural gas at typical pipeline operating pressures. The effects of different pressures, Reynolds numbers, and apparent drag were investigated. In accordance with the objectives, these tests have verified that the in-service repeatability and reproducibility of three typical 12-inch turbine meter, when used with high pressure natural gas, are better than the industry standard accuracy (plus or minus 1.0%).