首页> 美国政府科技报告 >Orifice Meter Installation Effects: Baseline Calibration of 10 Inch (250 mm)Diameter Orifice Meter in the GRI MRF High Pressure Loop. GRI Metering Research Facility Program. Topical Report
【24h】

Orifice Meter Installation Effects: Baseline Calibration of 10 Inch (250 mm)Diameter Orifice Meter in the GRI MRF High Pressure Loop. GRI Metering Research Facility Program. Topical Report

机译:孔板流量计安装效果:GRI mRF高压回路中10英寸(250 mm)直径孔板流量计的基线校准。 GRI计量研究设施计划。专题报道

获取原文

摘要

This memorandum presents the results of 10 inch (250 mm) diameter baseline(reference) orifice meter calibrations performed in the Gas Research Institute (GRI) Metering Research Facility (MRF) High Pressure Loop (HPL). The baseline calibration data will be used for comparison with orifice meter discharge coefficient data from orifice meter installation effects tests with and without flow conditioners. Two series of calibration tests were performed flowing natural gas at nominal pressures of 900 psia, 400 psia and 250 psia for six values of orifice ratio, 0.2, 0.4, 0.5, 0.6, 0.67 and 0.75.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号