首页> 美国政府科技报告 >Behavior of Hollow-Core FRP-Concrete-Steel Columns Subjected to Cyclic Axial Compression
【24h】

Behavior of Hollow-Core FRP-Concrete-Steel Columns Subjected to Cyclic Axial Compression

机译:空心FRp-混凝土 - 钢柱在循环轴压下的受力性能

获取原文

摘要

This report presents the results of an experimental study that was conducted to investigated the effects of key parameters on the compressive behavior of fiber reinforced polymer (FRP)-concrete-steel double-skin tubular columns (FSDT). Hybrid PSDT columns have been introduced as a new form of hybrid columns. They consist of an outer tube made of FRP and inner tube made of steel, with sandwiched concrete between them. This report investigated the effect of fiber angle and the ratio of steel tube diameter to its thickness (Di/ts) on the compressive behavior of FSDT columns. Ten FSDT cylinders with different (Di/ts) in addition to three concrete filled*fiber tuber (CFFT) cylinders were manufactured and tested under axial cyclic compression. The results of the experimental study indicate that the overall behavior of FSDT and CFFT is similar and the main difference in the capacity load. The cylinders with high D/T ratio achieve lower capacity than the normal capacity due to the local bucking of the steel tubes. Using the saturated fiber tube increases the axial ductility but does not give high confinement. These results are presented together with a discussion on the influence of the studied parameters on the compressive behavior of FSDTs.