首页> 美国政府科技报告 >Wind Induced Vibration of Stay Cables;Interim Final Report
【24h】

Wind Induced Vibration of Stay Cables;Interim Final Report

机译:斜拉索的风致振动;中期最终报告

获取原文

摘要

Cable-stayed bridges have become the form of choice over the past several decades for bridges in the medium to long span range. In come cases serviceability problems involving large amplitude vibrations of stay cables under certain wind and rain conditions have been observed. This study was conducted in order to develop a set of consistent design guidelines for mitigation of excess cable vibration on cable-stay bridges. In order to accomplish this objective the Project Team started with a thorough review of existing literature to determine the state of knowledge and identify any gaps that must be filled in order to enable the formation of a consistent set of design recommendations. This review indicated that while the rain/wind problem is known in sufficient detail, galloping of dry inclined cables was the most critical wind-induced vibration mechanism in need of further experimental research. A series of wind-tunnel tests was performed to study this mechanism. Analytical and experimental research was performed to study mitigation methods, Covering a range of linear and non-linear dampers and cross-ties. The study also included brief studies on live load induced vibration and establishing driver/pedestrian comfort criteria. Based on the above, design guidelines for mitigation of wind-induced vibrations of stay cables were developed.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号