首页> 美国政府科技报告 >Mass of Chlorinated Volatile Organic Compounds Removed by Pump-and-Treat, Naval Air Warfare Center, West Trenton, New Jersey, 1996-2010
【24h】

Mass of Chlorinated Volatile Organic Compounds Removed by Pump-and-Treat, Naval Air Warfare Center, West Trenton, New Jersey, 1996-2010

机译:1996 - 2010年,新泽西州西特伦顿海军空战中心泵送和处理氯化挥发性有机化合物的质量

获取原文

摘要

Pump and Treat (P&T) remediation is the primary technique used to contain and remove trichloroethylene (TCE) and its degradation products cis 1-2,dichloroethylene (cDCE) and vinyl chloride (VC) from groundwater at the Naval Air Warfare Center (NAWC), West Trenton, NJ. Three methods were used to determine the masses of TCE, cDCE, and VC removed from groundwater by the P&T system since it became fully operational in 1996. Method 1, is based on the flow volume and concentrations of TCE, cDCE, and VC in groundwater that entered the P&T building as influent. Method 2 is based on withdrawal volume from each active recovery well and the concentrations of TCE, cDCE, and VC in the water samples from each well. Method 3 compares the maximum monthly amount of TCE, cDCE, and VC from Method 1 and Method 2. The greater of the two values is selected to represent the masses of TCE, cDCE and VC removed from groundwater each month.