Final temperatures attained for various heater posers are shown in Table I for four sets of conditions. Free and forced convection are considered as are two ambient temperatures. Experimental confirmation within 10% of the calculated values was obtained with the one set of conditions tested.nFor free convection the time constant (time required for case to reach 63% of final temperature) was 44 min., and fro forced convection was 10 min.