首页> 美国政府科技报告 >Continuous Cooling Transformation Diagrams I -Cooling Curve Analysis for Transformation Diagrams and Heat Treatment,
【24h】

Continuous Cooling Transformation Diagrams I -Cooling Curve Analysis for Transformation Diagrams and Heat Treatment,

机译:连续冷却转换图I - 转换图和热处理的曲线分析,

获取原文

摘要

Based upon the earlier work on the cooling of round steel bars in inch measurement,these newer tables extend the assessment in the metric millimetre sizes. Air cooling covers 0.01to 2000mm dia and oil and water quenching from 1to 300mm. Axial,mid radius and near surface (0.8R) cooling rates are considered and analysis tables are provided. Equivalent diameter tables are provided for similar nucleation by air,oil and water cooling. A brief description of the determination of progress of transformation and the preparation of continuous cooling transformation diagrams is illustrated for En 16. (Author)