Fire Test of Fiberglass Reinforced Plastic Structural Wall Panel.

机译:玻璃纤维增​​强塑料结构墙板的耐火试验。

获取原文

摘要

The report describes a test conducted to determine the performance of a load-bearing glass fiber reinforced polyester wall system when subjected to the standard fire conditions described in ASTM E119,Fire Tests of Building Construction and Materials. The structural composite is a glass fiber reinforced polyester laminate manufactured from random oriented glass fibers and impregnated with specially formulated polyester resins. The composite contains a large percentage of inorganic fillers. It was concluded that the wall panel passed the thermal requirements for a 30minute load-bearing fire rating. (Author) Portions of this document are not fully legible.