首页> 美国政府科技报告 >Comparison of Thermally Coated and Uninsulated Rail Tank Cars Filled with LPG Subjected to a Fire Environment.
【24h】

Comparison of Thermally Coated and Uninsulated Rail Tank Cars Filled with LPG Subjected to a Fire Environment.

机译:在火灾环境下填充LpG的热涂层和非绝缘轨道油罐车的比较。

获取原文

摘要

Two fire tests were conducted on 128 kiloliter,high pressure rail tank cars filled with liquified petroleum gas. Both tank cars were exposed to an intense hydrocarbon fire after being outfitted with appropriate instrumentation. The instrumentation was monitored and its output recorded throughout the fire tests. To test the feasibility of insulating railroad tank cars to protect them from fire exposure,one of the cars was coated with a 0.318cm thermal shield. A comparison of data conclusively shows that a thermal shield significantly alters the thermal response of a rail tank car in a fire environment.