The principal findings of the Optical Manufacturers Association's Research Associate Program are summarized. The limitations of the present drop ball test for impact resistance are discussed. Essentially,only a small part of the lens surface and a small part of the edge are subjected to sufficiently high stresses. It is therefore desirable to replace the drop ball test with a sampling procedure from which meaningful information on lens quality can be obtained. Some aspects of the design of a sampling plan,in which the overall quality of a laboratory's lenses is monitored by periodically testing a set of coupon lenses,are discussed.