首页> 美国政府科技报告 >Functional Performance of the Helical Coil Steam Generator,Consolidated Nuclear Steam Generator (CNSG) IV System.
【24h】

Functional Performance of the Helical Coil Steam Generator,Consolidated Nuclear Steam Generator (CNSG) IV System.

机译:螺旋线圈蒸汽发生器,联合核蒸汽发生器(CNsG)IV系统的功能性能。

获取原文

摘要

The objective of this project was to study the functional performance of the CNSG -IV helical steam generator to demonstrate that the generator meets steady-state and transient thermal-hydraulic performance specifications and that secondary flow instability will not be a problem. Economic success of the CNSG concepts depends to a great extent on minimizing the size of the steam generator and the reactor vessel for ship installation. Also,for marine application the system must meet stringent specifications for operating stability,transient response,and control. The full-size two-tube experimental unit differed from the CNSG only in the number of tubes and the mode of primary flow. In general,the functional performance test demonstrated that the helical steam generator concept will exceed the specified superheat of 35F at 100% load. The experimental measured superheat at comparable operating conditions was 95F. Testing also revealed that available computer codes accurately predict trends and overall performance characteristics.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有