首页> 美国政府科技报告 >Hazard Evaluation and Technical Assistance Report No. TA-76-111, U.S. Secret Service Vehicle Garage, Washington, DC
【24h】

Hazard Evaluation and Technical Assistance Report No. TA-76-111, U.S. Secret Service Vehicle Garage, Washington, DC

机译:危险评估和技术援助报告Ta-76-111,美国特勤局车库,华盛顿特区

获取原文

摘要

Exposures to carbon-monoxide (630080) (CO) nitrogen-dioxide (10102440) (NO2), and nitric-oxide (10102439) were surveyed at the United States Secret Service (SIC-7525) Department of the Treasury, vehicle garage in Washington, D.C., on October 28, 1976. The survey was requested by the Chief of Administrative Operations Division, United States Secret Service, Department of the Treasury on behalf of an unspecified number of garage employees. Breath analyses for 7 workers revealed elevated carboxyhemoglobin (COHb) concentrations, but only 2 exceeded the OSHA standard of 50 parts per million, and these were found in heavy smokers. Nonsmokers did not exceed criteria, but did have elevated COHb. In air, CO concentrations were well within OSHA standards of 50 parts per million for an 8 hour time weighted average. No detectable concentrations of nitrogen-dioxide or nitrous-oxide were found. The author recommends that malfunctioning garage doors be repaired, outside air intake be kept clear of debris, automobiles be prohibited from parking at the outside air intake, local exhaust system be used when cars are serviced, and an inspection, test and evaluation of the ventilation system be performed to ensure its optimum operation.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号