首页> 美国政府科技报告 >SF6 Tracer Gas Tests of Bagging-Machine Hood Enclosures
【24h】

SF6 Tracer Gas Tests of Bagging-Machine Hood Enclosures

机译:袋装机罩的sF6示踪气体测试

获取原文

摘要

This Bureau of Mines report presents the results of tracer gas studies conducted at three facilities where bagger hoods had been installed several years ago to remove airborne silica dust from the vicinity of the bagging operator. The studies indicated that for optimum benefits makeup air must be evenly dispersed, the hood enclosures and duct systems must be as airtight as possible, the average intake air velocity of each hood should be at least 200 fpm, and the hoods and duct systems must be properly maintained.