首页> 美国政府科技报告 >Health Hazard Evaluation and Technical Assistance Report No. TA-80-062-852, Seattle Air Traffic Control Center (FAA), Auburn, Washington
【24h】

Health Hazard Evaluation and Technical Assistance Report No. TA-80-062-852, Seattle Air Traffic Control Center (FAA), Auburn, Washington

机译:健康危害评估和技术援助报告编号Ta-80-062-852,西雅图空中交通管制中心(Faa),华盛顿州奥本市

获取原文

摘要

Ionizing and nonionizing radiation measurements were taken at the Seattle Air Traffic Control Center (FAA), (SIC-3662), in Auburn, Washington, on June 26, and July 21 and 22, 1980. A representative of the Professional Air Traffic Controller's Organization requested the evaluation on behalf of an employee at the center who claimed that a cataract in his eye lens resulted from work related radiation exposure. Radar scope measurements were at background radiation levels with no hot spots detected. All measured radiation levels generally were far below the permissible exposure limits; however, the magnetic field measurement at 2 centimeters from the emergency array antenna was slightly above the OSHA evaluation criteria of 0.5 amperes per meter. The electric field measurement was below the 200 volts per meter OSHA criteria. Both fields were below detectable levels at a distance of 15 centimeters. The authors conclude that a hazard from ionizing and nonionizing radiation did not exist at this facility. Measured radiation levels at this worksite should not produce cataracts in exposed personnel. The authors recommend that access to the emergency array antenna be limited.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信