首页> 美国政府科技报告 >Characteristics of a Radon Diffusion Chamber with Electrical Collection Using Plastic Nuclear Track Detectors
【24h】

Characteristics of a Radon Diffusion Chamber with Electrical Collection Using Plastic Nuclear Track Detectors

机译:利用塑料核径迹探测器进行电气收集的氡扩散室的特性

获取原文

摘要

A portable radon diffusion chamber was tested with electrical collection of radon daughter nuclei for enhancement of sensitivity. The detector was small enough to be worn suspended from a belt. With a battery-supplied high voltage, the sensitivity was found to be 1.43 tracks/sq cm per pCi-h/lambda of ambient radon at 50% relative humidity. The track densities on the surfaces of the CR-39 plastic nuclear track detectors were found to be nonuniform, making the determination of average densities with high accuracy difficult. The fabrication of electrets for use in the detector was investigated in accordance with published techniques with negative results.