首页> 美国政府科技报告 >Transient Horizontal Flame Spread Tests on Cellular Plastics - Experimental Results: Volume 2 and Volume 3
【24h】

Transient Horizontal Flame Spread Tests on Cellular Plastics - Experimental Results: Volume 2 and Volume 3

机译:多孔塑料的瞬态水平火焰蔓延试验 - 实验结果:第2卷和第3卷

获取原文

摘要

Experimental results from measurements of the characteristics of transient horizontal flame spread over cellular plastics under the influence of external radiation are presented. The experiments involve flame spread from point ignition to radii of about 0.3 m. A single wax match is sued for ignition. The measurements made include the radial spread of fire, mass pyrolysis rate, radiative and convective power released by fire and the production and consumption of gas species by fire. The efficiency of burning of various plastics is also presented. The plastics used are primarily cellular foams obtained from the PRC materials bank. The maximum external radiative flux used is 0.85 w/sq cm. Volume 1 contains the description and discussion of the experimental procedures and computations. Volumes 2 and 3 contain experimental data and summary of the empirical physical and chemical data reduced from the experimental data, respectively.