首页> 美国政府科技报告 >Determination of Correlation between Nuclear Moisture/Density Tests and Standard Tests on Certain Gravel Bases in Southern Arkansas
【24h】

Determination of Correlation between Nuclear Moisture/Density Tests and Standard Tests on Certain Gravel Bases in Southern Arkansas

机译:确定阿肯色州南部某些砾石基层的核水分/密度试验与标准试验的相关性

获取原文

摘要

The nuclear method presented inconsistent results when applied to density and moisture of a gravel base material in the Southwest, AR, Nashville area. Nuclear wet densities were lower (4-18 pcf) than the sand cone wet densities. Nuclear moistures appeared to be higher than the oven dry moisture. A correlation study between laboratory nuclear and actual results showed (1) that the correlation nuclear-actual wet density is linear and the difference between them increases as wet density increases; (2) that nuclear moisture can be lower as well as higher than the oven dry moisture and the correlation between them is linear also; (3) that nuclear-actual dry density correlate very poorly. It is the objective of the study to propose a simple procedure for calibration of the nuclear gage for soils that show soil composition error.