首页> 美国政府科技报告 >Fatal Accident Circumstances and Epidemiology (FACE) Report: Confined Space Incident Kills Two Workers - Company Employee and Rescuing Fireman
【24h】

Fatal Accident Circumstances and Epidemiology (FACE) Report: Confined Space Incident Kills Two Workers - Company Employee and Rescuing Fireman

机译:致命事故情况和流行病学(FaCE)报告:密闭空间事件导致两名工人丧生 - 公司员工和抢救消防员

获取原文

摘要

A fatal accident circumstance and epidemiology report on an incident occurring in a confined space and involving two fatalities is presented. Two employees of a petroleum company were determining whether an empty 10,000 gallon toluene tank needed cleaning. Due to limited visibility, one worker decided to enter the tank. As he descended through a 16 inch opening in the top of the tank, he apparently fell into the tank. The other worker called the city fire department. The responding unit decided to use a K 12 saw to cut an opening in the side of the tank. Although water sprays were used to minimize spark generation, an explosion occurred and a fireman was killed by the concussion. Preliminary medical information indicates that the worker inside the tank was dead prior to the explosion. Recommendations include city fire departments establishing a registry of confined spaces and toxic or explosive substances in the area in which they serve and conducting research to determine the best methods to gain entry into enclosed spaces containing inflammable or explosive atmospheres.