首页> 美国政府科技报告 >In-Depth Survey Report: Evaluation of Brake Drum Service Controls at Cincinnati Bell Maintenance Facility, Fairfax, Ohio
【24h】

In-Depth Survey Report: Evaluation of Brake Drum Service Controls at Cincinnati Bell Maintenance Facility, Fairfax, Ohio

机译:深入调查报告:评估俄亥俄州费尔法克斯辛辛那提贝尔维修设施的制动鼓维修控制

获取原文

摘要

The effectiveness of vacuum units (Nilfisk Asbestos-Clene System) equipped with high efficiency particulate air filters in limiting exposure to asbestos (1332214) during the servicing of automotive brakes was evaluated. Brake servicing of seven vehicles at the Cincinnati Bell Fairfax Garage was studied. Phase contrast microscope (PCM) analyses of personal air samples, collected for the duration of a single brake job or for 2 hours, whichever was longer, yielded counts ranging from 0.004 fiber per cubic centimeter (f/cc) (detection limit) to 0.016f/cc using an aspect ratio of 5:1. Effective control was evidenced by the low exposures for the brake mechanics; 79 percent of the air samples, including personal, axle, fender, background, and ambient samples were below detectable limits. Transmission electron microscopy also showed very low asbestos concentrations. The authors caution that workers should not use a dry cloth to clean hands after finishing a brake job. Instructions are offered for safe removal and replacement of the various filters in vacuum units.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号