首页> 美国政府科技报告 >Round-Robin Measurements of the Apparent Thermal Conductivity of Two Refractory Insulation Materials, Using High-Temperature Guarded-Hot-Plate Apparatus
【24h】

Round-Robin Measurements of the Apparent Thermal Conductivity of Two Refractory Insulation Materials, Using High-Temperature Guarded-Hot-Plate Apparatus

机译:使用高温防护热板装置测量两种耐火绝缘材料的表观导热系数的循环测量

获取原文

摘要

The report presents the test results and analysis of round-robin measurements of apparent thermal conductivity for two kinds of refractory insulation board using high-temperature guarded-hot-plate apparatus. The round robin was carried out under the sponsorship of the American Society for Testing and Materials (ASTM) Subcommittee C-16.30 on Thermal Measurements. To complete the measurement program in a timely manner the participants chose to measure different specimens, selected, however, from the same production lot. The test results for apparent thermal conductivity illustrate the inter-laboratory reproducibility as well as the temperature and density dependence. The data include the temperature range from 297 to 773 K. The standard deviation is 7.4% for the 48 test results reported by seven participating laboratories for fibrous alumina-silica. The standard deviation is 8.0% for the 58 test results reported for calcium silicate.