首页> 美国政府科技报告 >Evaluation Retest on a Hospital Refuse Incinerator at Sutter General Hospital, Sacramento, California
【24h】

Evaluation Retest on a Hospital Refuse Incinerator at Sutter General Hospital, Sacramento, California

机译:加利福尼亚州萨克拉门托sutter综合医院医院垃圾焚烧炉的评估重新测试

获取原文

摘要

An evaluation test program was conducted to evaluate the effect of incinerator design changes on emissions from the hospital refuse incinerator. The test was conducted as a part of the California Air Resources Board's program to assess emissions from stationary sources. Daily average oxygen concentrations ranged from 12.1-15.6% and the daily average carbon dioxide concentrations ranged from 4.0-5.5%. Dioxin emissions ranged from 21.0 nanograms per second (ng/sec) for tetrachlorodioxin to 355 ng/sec for the heptachlorodioxin. Furan emission rates ranged from 253 ng/sec for the tetrachlorofuran to 477 ng/sec for the heptachlorofuran. The mass emission rates of hydrochloric acid ranged from 2.6 to 5.8 pounds per hour.