The U.S. Bureau of Mines has established a method for the calibration of class 2 and class 4 standards of mass using a procedure from designs developed by the National Institute of Standards and Technology (NIST). The method produces a weight calibration that is within 1.0 pct of the balance sensitivity. A set of four 1-kg weights yielded a standard deviation of 3.25 mg compared to plus or minus 2.91 mg balance sensitivity. The weight employs the use of a high-accuracy balance to measure the difference between a set of weights calibrated by NIST and the set to be calibrated. The error of the balance is included in the error for each weight calibrated.