首页> 美国政府科技报告 >Heat Transfer in a Compact Tubular Heat Exchanger with Helium Gas at 3.5 MPa
【24h】

Heat Transfer in a Compact Tubular Heat Exchanger with Helium Gas at 3.5 MPa

机译:用氦气在3.5 mpa下的紧凑型管式换热器中的传热

获取原文

摘要

The authors constructed a compact heat exchanger consisting of circular tubes in parallel brazed to a grooved base plate. This tube specimen heat exchanger was tested in an apparatus which radiatively heated the specimen on one side at a heat flux of up to 54 W/cm sq, and cooled the specimen with helium gas at 3.5 MPa and Reynolds numbers of 3000 to 35,000. The measured friction factor of the tube specimen was lower than that of a circular tube with fully developed turbulent flow, although our uncertainty was high due to entrance and exit losses. The measured Nusselt number, when modified to account for differences in fluid properties between the wall and the cooling fluid, agreed with past correlations for fully developed turbulent flow in circular tubes.