首页> 美国政府科技报告 >Branch Chamber System and Techniques for Simultaneous Pollutant ExposureExperiments and Gaseous Flux Determinations
【24h】

Branch Chamber System and Techniques for Simultaneous Pollutant ExposureExperiments and Gaseous Flux Determinations

机译:分支室系统和同时污染物暴露实验和气体通量测定技术

获取原文

摘要

The authors describe an experimental system and techniques for use insimultaneous pollutant exposure experiments and gaseous flux determinations. The system uses flexible Teflon bag-like chambers to enclose entire individual branches of young trees. Five gaseous fluxes (CO2, H2O, SO2, O3, and H2O2) are measured once per hour for each of two branches. Techniques for determining chamber surface loss corrections and methods of estimating needle surface area of conifers are described. A three-week continuous test was run in order to evaluate system performance. Inlet concentrations of the five gases were extremely stable, with uncertainties of <2.2% in all cases and day-to-night differences of <4%. Comparison of two branch chambers, one with clean air and one with the added pollutant gases H2O2, SO2, and O3, showed that between-chamber differences were <2% for the average inlet concentrations of H2O and CO2. Pollutant losses to chamber surfaces were significant but were generally smaller than losses to the branch itself. Chamber loss corrections were different for daytime and nighttime conditions and also evolved as the three-week experiment proceeded.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号