Preliminary Report on the Baseline Thermal and Hydraulic Performance Tests of a Sieve Tray Direct Contact Heat Exchanger

机译:筛板式直接接触式换热器基线热力学和水力性能试验初报

获取原文

摘要

A sieve tray direct contact heat exchanger was designed, built and then tested in a binary power cycle at the Raft River geothermal test site. A series of baseline thermal and hydraulic tests were conducted with an isobutane working fluid. The evaluation of these tests is reported. The testing of the DCHX confirmed that the repeated forming and coalescence of the working fluid drops in the sieve tray column produce excellent heat transfer performance. Tray thermal efficiencies were at or above the design value of 70% and the pinch points were well under the design goal of 1 exp 0 F (too small to be measured with installed instrumentation). From a hydraulic standpoint, the column operated at the working fluid velocities from the plate holes corresponding to the predicted condition of maximum total drop surface area (or minimum drop size) when the unit was operating near the flooding limits, or throughputs. This is the recommended working fluid hole velocity for use in designing sieve tray columns. The geothermal flow limits encountered (at flooding) corresponded roughly to the thermal rise velocity of a 1/32-inch drop. This is a drop size commonly used for specifying the terminal velocity (or continuous fluid velocity) in the design of columns for mass transfer applications. (ERA citation 08:014586)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号