首页> 美国政府科技报告 >Malfunction of Television Camera Monitor on Command Module
【24h】

Malfunction of Television Camera Monitor on Command Module

机译:指令模块上电视摄像机监视器故障

获取原文

摘要

The commond module television camera monitor exhibited loss of horizontal synchronization during the initial usage. This condition cleared and performance of the monitor was normal until the press conference telecast during the transearth coast phase. At that time, the monitor had the same horizontal synchronization problem reported during the initial usage. The horizontal hold control adjustment would not correct the condition. The monitor was turned off for approximately 5 minutes, then turned back on, after which the monitor's picture was normal. The loss of horizontal synchronization was most likely caused by either an intermittent condition in the precision voltage regulator circuit assembly in the low voltage power supply, or the shift of the stable range of the horizontal potentiometer setting when warming up after turn-on. (Author)