首页> 美国政府科技报告 >Rotor tip clearance effects on overall and blade-element performance of axial-flow transonic fan stage
【24h】

Rotor tip clearance effects on overall and blade-element performance of axial-flow transonic fan stage

机译:转子叶尖间隙对轴流式跨音速风扇级的整体和叶片元件性能有影响

获取原文

摘要

The effects of tip clearance on the overall and blade-element performance of an axial-flow transonic fan stage are presented. The 50-centimeter-diameter fan was tested at four tip clearances (nonrotating) from 0.061 to 0.178 centimeter. The calculated radial growth of the blades was 0.040 centimeter at design conditions. The decrease in overall stage performance with increasing clearance is attributed to the loss in rotor performance. For the rotor the effects of clearance on performance parameters extended to about 70 percent of blade span from the tip. The stage still margin based on an assumed operating line decreased from 15.3 to 0 percent as the clearance increased from 0.061 to 0.178 centimeter.