首页> 美国政府科技报告 >Upgrading and Performance of the Sao Laser Ranging System in Matera, Italy
【24h】

Upgrading and Performance of the Sao Laser Ranging System in Matera, Italy

机译:意大利马泰拉骚式激光测距系统的升级与性能

获取原文

摘要

The performance of the SAO lasers was improved considerably in terms of accuracy, range noise, data yield, and reliability. With the narrower laser pulse (2.5-3.0 nsec) and a new analog pulse processing system, the systematic range errors were reduced to 3-5 cm and range noise has been reduced to 5-15 cm on low satellites and 10-18 cm on Lageos. Pulse repetition rate was increased to 30 ppm and considerable improvement has been made in signal-to-noise ratio by using a 3 Angstrom interference filter and by reducing the range gate window down to 200-400 nsec. The first upgraded system was installed in Arequipa, Peru in the spring of 1982. The second upgraded system is now in operation in Matera, Italy. The third system is expected to be installed in Israel during 1984.