首页> 美国政府科技报告 >Evaluation of Two Crew Module Boilerplate Tests Using Newly Developed Calibration Metrics.
【24h】

Evaluation of Two Crew Module Boilerplate Tests Using Newly Developed Calibration Metrics.

机译:使用新开发的校准度量评估两个船员模块锅炉板测试。

获取原文

摘要

The paper discusses a application of multi-dimensional calibration metrics to evaluate pressure data from water drop tests of the Max Launch Abort System (MLAS) crew module boilerplate. Specifically, three metrics are discussed: 1) a metric to assess the probability of enveloping the measured data with the model, 2) a multi-dimensional orthogonality metric to assess model adequacy between test and analysis, and 3) a prediction error metric to conduct sensor placement to minimize pressure prediction errors. Data from similar (nearly repeated) capsule drop tests shows significant variability in the measured pressure responses. When compared to expected variability using model predictions, it is demonstrated that the measured variability cannot be explained by the model under the current uncertainty assumptions.