Lock-up failure of a four-bar linkage deployment mechanism

机译:四连杆部署机制的锁定故障

获取原文

摘要

A successful failure investigation of a four-bar linkage deployment mechanism has been performed. Possible failure causes such as the mismatch of material coefficient of thermal expansion (CTE), excessive hinge friction, limit switch interference, and thermal gradient induced resistive preload were investigated and are discussed. The final conclusions and corrective actions taken are described. Finally, valuable lessons learned during the investigation are discussed.