首页> 美国政府科技报告 >A PRELIMINARY STUDY OF MACHINE-COUNTERSUNK FLUSH RIVETS SUBJECTED TO A COMBINED STATIC AND ALTERNATING SHEAR LOAD
【24h】

A PRELIMINARY STUDY OF MACHINE-COUNTERSUNK FLUSH RIVETS SUBJECTED TO A COMBINED STATIC AND ALTERNATING SHEAR LOAD

机译:一种复合静态和交替剪切载荷的机 - 反冲铆钉的初步研究

获取原文

摘要

In previous studies of the tightness and flushness of machine—countersunk flush rivets (references 1 to 3) it has been found that, if the countersunk head protrudes above the sheet surface before the rivet is driven, a much tighter riveted joint is obtained than if the counter sunk head is below the sheet surface before the rivet is driven. The purpose of the present investigation is to study the effect of the height of the rivet head on the number of cycles required to cause failure of a machine countersunk flush—riveted joint under a combined static and alternating shear load.

著录项

  • 作者

    Harold Crate;

  • 作者单位
  • 年度 1943
  • 页码 1-9
  • 总页数 9
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工业技术;