首页> 美国政府科技报告 >Operating temperatures of a sodium-cooled exhaust valve as measured by a thermocouple
【24h】

Operating temperatures of a sodium-cooled exhaust valve as measured by a thermocouple

机译:通过热电偶测量的钠冷排气阀的工作温度

获取原文

摘要

Report presents the results of a thermocouple installed in the crown of a sodium-cooled exhaust valve. The valve was tested in an air-cooled engine cylinder and valve temperatures under various engine operating conditions were determined. A temperature of 1337 degrees F. was observed at a fuel-air ratio of 0.064, a brake mean effective pressure of 179 pounds per square inch, and an engine speed of 2000 r.p.m. Fuel-air ratio was found to have a large influence on valve temperature, but cooling-air pressure and variation in spark advance had little effect. An increase in engine power by change of speed or mean effective pressure increased the valve temperature. It was found that the temperature of the rear-spark-plug bushing was not a satisfactory indication of the temperature of the exhaust valve.