首页> 美国政府科技报告 >Correlation of forced-convection heat-transfer data for air flowing in smooth platinum tube with long-approach entrance at high surface and inlet-air temperatures
【24h】

Correlation of forced-convection heat-transfer data for air flowing in smooth platinum tube with long-approach entrance at high surface and inlet-air temperatures

机译:光滑铂管中空气强制对流传热数据与高表面和进气温度下长入口的相关性

获取原文

摘要

A heat-transfer investigation was conducted with air in an electrically heated platinum tube with long-approach entrance, inside diameter of 0.525 inch, and effective heat-transfer length of 24 inches over ranges of Reynolds number up to 320,000, average inside-tube-wall temperature up to 3053 degrees R, and inlet-air temperature up to 1165 degrees R. Correlation of data by the conventional Nusselt relation resulted in separation of data with tube-wall temperature. Good correlation was obtained, however, by use of a modified Reynolds number.