首页> 美国政府科技报告 >Assessment of RELAPS/MOD2 against a 10% Load Rejection Transient from 75% Steady State in the Vandellos II Nuclear Power Plant. International Agreement Report
【24h】

Assessment of RELAPS/MOD2 against a 10% Load Rejection Transient from 75% Steady State in the Vandellos II Nuclear Power Plant. International Agreement Report

机译:评估RELaps / mOD2对Vandellos II核电厂75%稳态的10%负载抑制瞬态。国际协议报告

获取原文

摘要

The Consejo de Seguridad Nuclear (CSN) and the Asociacion Nuclear Vandellos (ANV) have developed a model of Vandellos II Nuclear Power Plant. The ANV collaboration consisted in the supply of design and actual data, the cooperation in the simulation of the control systems and other model components, as well as in the results analysis. The obtained model has been assessed against the following transients occurred in plant: A trip from the 100 percent power level (CSN); A load rejection from 100 percent to 50 percent (CSN); A load rejection from 75 percent to 65 percent (ANV); and A feedwater turbopump trip (ANV). The report describes a load rejection from 75 percent to 65 percent transient simulation. The transient was one of the tests carried out in Vandellos II NPP during the startup tests.

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有