首页> 美国政府科技报告 >Test plan for Enraf Series 854 level gauge testing in Tank 241-S-106
【24h】

Test plan for Enraf Series 854 level gauge testing in Tank 241-S-106

机译:在241-s-106储罐中进行Enraf series 854液位计测试的测试计划

获取原文

摘要

An Enraf Series 854 level gauge was installed on Tank 241-S-106 (S-106) during the first week of June 1994. On August 11, 1994, the gauge's measuring wire broke. An investigation has been started to determine how the wire broke. This test plan identifies a qualification test that is part of this investigation. This test will also provide evidence as to the location and extent of potential corrosion on the measuring wire due to tank environment. The results from this testing will provide data for better material selections. This test will involve placing the existing Enraf Series 854 level gauge back into service with the same type of measuring wire (316 stainless steel) that originally broke on August 11, 1994. The gauge will be operated for 14 days. At the end of the 14-day test, the wire shall be sent to Pacific Northwest Laboratory (PNL) for analysis.