首页> 美国政府科技报告 >Deactivation of tracer-flo equipment thru retrieval of its radioactive Krypton-85 gas
【24h】

Deactivation of tracer-flo equipment thru retrieval of its radioactive Krypton-85 gas

机译:通过回收其放射性氪-85气体来灭活示踪装置

获取原文

摘要

The rules and regulations on safe transport of radioactive materials require Kr-85 gas to be transported in an approved container. A new innovative technique/procedure in deactivating tracer-flo equipment i.e., without separation of the Kr-85 from the nitrogen was developed by the authors. The developed procedure was successfully applied in four tracer-flo equipment of three (3) semiconductor firms. In the process, the three firms have saved about US$ 28,000.00 (P 800,000.00) if the deactivation were undertaken by a foreign service company. The Philippine Nuclear Research Institute (PNRI) retrieved about P 382,000.00 worth of Kr-85 that could be used in industrial applications such as leak tracing of buried pipes, etc. (author). 1 ref.; 5 figs. (Atomindex citation 26:037428)