This design review examined the design documents contained in a notebook prepared for the final design review of the multiport riser assembly. This assembly will support the Hydrogen Mitigation Test program for mitigation of safety issues for Hanford Waste Tank 241-SY-101. The purpose of the Multiport Riser is to provide multiple access ports of several diameters in a single 42 inch riser for simultaneous access of test and support equipment. The notebook was titled: (open quotes)Multiport Riser Final Design Review.(close quotes) The review was conducted using a database comment registration system whereby the reviewer comments were entered into the database and each comment was given a unique identifier. During the review, each comment was referred to by its identifier. Changes to comments, responses, and actions needed were made with the agreement of the committee and the reviewers at the formal design review meeting held March 1, 1994. When the structural analyses were available, they were distributed for review which allowed closure of all design review comments. Approval of the design was achieved and supporting documents are included in this report.